Initialising ...
Initialising ...
Initialising ...
Initialising ...
Initialising ...
Initialising ...
Initialising ...
Miyamoto, Yutaka; Yasuda, Kenichiro; Magara, Masaaki
Journal of Radioanalytical and Nuclear Chemistry, 309(1), p.303 - 308, 2016/07
Times Cited Count:2 Percentile:19.71(Chemistry, Analytical)The technique of sequential separation for U, Th, Pb, lanthanides and Pu using a single anion-exchange column and mixed acids media were developed. An automatic system utilizing a small column and pressurized gas was assembled for this sequential separation. By adjusting the eluent chemical composition for Pu separation, this separation technique has been achieved. Some pieces of tree ring sample were digested, and ultra-trace U and Pu in the samples were separated by this system. The analytical results of U and Pu measured by mass spectrometry will be mentioned.
Miyamoto, Yutaka; Yasuda, Kenichiro; Magara, Masaaki
KEK Proceedings 2015-4, p.44 - 48, 2015/11
We developed an automatic system for sequential separation with an anion-exchange column to simply and quickly separate less than pico-grams of ultra-trace U, Th, Pb, the lanthanide, and Pu in an environmental sample without foreign contamination. The objective sequential separation of ultra-trace multi-elements succeeded by choosing the HCl-HF mixture based acetic acid for Th separation and the HCl-diluted HF mixture for Pu separation. The objective elements in a multi-elements mixture were completely separated for 6 h 15 min by use of the automatic system and the optimized separation condition.
Miyamoto, Yutaka; Suzuki, Daisuke; Esaka, Fumitaka; Magara, Masaaki
Analytical and Bioanalytical Chemistry, 407(23), p.7165 - 7173, 2015/09
Times Cited Count:8 Percentile:31.37(Biochemical Research Methods)Age of individual uranium-plutonium mixed particles with various U/Pu atomic ratios were determined by inductively-coupled plasma mass spectrometry. Micron-sized particles were prepared from U and Pu certified reference materials. The Pu reference was stored for 4-6 years since the last purification. The Pu purification age was obtained from the Am/Pu ratio which was calculated from the product of three measured ratios of Pu and Am isotopes in the eluted fractions. Am, U and Pu in a sample solution were sequentially separated a small anion-exchange column. The Am/Pu ratio was accurately determined by spiking pure Am to the sample solution. The determined age of particles with various U/Pu ratios was in good agreement with the expected age with high accuracy and high precision.
Miyamoto, Yutaka; Yasuda, Kenichiro; Magara, Masaaki
Analyst, 140(13), p.4482 - 4488, 2015/07
Times Cited Count:6 Percentile:21.67(Chemistry, Analytical)Uranium, Thorium, lead, and the lanthanides were automatically and sequentially separated with a single anion-exchange column. This separation was achieved using eluents consisting of simple and highly pure acid mixture of HCl, HNO, acetic acid, and HF. This simple, automatic system is driven with pressurized nitrogen gas, and controlled by a computer program. For an evaluation examination, a reference powdered rock sample was separated by using this system. Abundances of objective elements, including 0.23 ng of lutetium, were accurately determined without corrections of chemical recovery yield or subtraction of processing blank. This separation technique saves time and effort for chemical processing, and it is useful for ultra-trace quantitative and isotopic analyses of elements in small environmental samples.
Magara, Masaaki; Usuda, Shigekazu; Sakurai, Satoshi; Watanabe, Kazuo; Esaka, Fumitaka; Hirayama, Fumio; Lee, C. G.; Yasuda, Kenichiro; Kono, Nobuaki; Inagawa, Jun; et al.
Dai-26-Kai Kaku Busshitsu Kanri Gakkai (INMM) Nihon Shibu Nenji Taikai Rombunshu, p.157 - 164, 2005/00
JAERI has conducted the analysis of domestic and the IAEA samples. JAERI is developing the analytical techniques to improve the analytical ability for the safeguards environmental samples. For bulk analysis, study is focused on the improvement of reliability of isotope ratio measurements by ICP-MS. New chemical separation techniques are under development and a desolvation module is introduced to reduce the polyatomic interferences. In particle analysis, the sample preparation procedure for SIMS method is modified to measure the U/U and U/U ratios for individual particles. We are also developing fission track-TIMS method to measure uranium isotope ratios in particles of sub-micrometer size. A screening instrument of X-ray fluorescent analysis is equipped to measure elemental distribution on a swipe surface.
Usuda, Shigekazu
Kagaku To Kyoiku, 51(10), p.612 - 613, 2003/10
no abstracts in English
Usuda, Shigekazu
Kaku Busshitsu Kanri Senta Nyusu, 32(7), p.10 - 11, 2003/07
no abstracts in English
Hatsukawa, Yuichi; Toh, Yosuke; Oshima, Masumi; Hayakawa, Takehito; Shinohara, Nobuo; Kushita, Kohei; Ueno, Takashi; Toyoda, Kazuhiro*
Journal of Radioanalytical and Nuclear Chemistry, 255(1), p.111 - 113, 2003/01
Times Cited Count:12 Percentile:62.23(Chemistry, Analytical)no abstracts in English
Yasuda, Kenichiro; Mori, Masahito*; Miyamoto, Yutaka; Magara, Masaaki; Sakurai, Satoshi; Usuda, Shigekazu
Journal of Nuclear Science and Technology, 39(Suppl.3), p.576 - 578, 2002/11
no abstracts in English
Magara, Masaaki; Sakakibara, Takaaki; Kurosawa, Setsumi; Takahashi, Masato; Sakurai, Satoshi; Hanzawa, Yukiko; Esaka, Fumitaka; Watanabe, Kazuo; Usuda, Shigekazu
Journal of Analytical Atomic Spectrometry, 17(9), p.1157 - 1160, 2002/09
Times Cited Count:11 Percentile:44.18(Chemistry, Analytical)no abstracts in English
Miyabe, Masabumi; Geppert, C.*; Oba, Masaki; Wakaida, Ikuo; Wendt, K.*
Journal of Physics B; Atomic, Molecular and Optical Physics, 35(18), p.3865 - 3877, 2002/09
Times Cited Count:12 Percentile:50.16(Optics)no abstracts in English
Sakurai, Satoshi; Hanzawa, Yukiko; Magara, Masaaki; Usuda, Shigekazu; Watanabe, Kazuo; Adachi, Takeo
Kuki Seijo, 39(6), p.404 - 410, 2002/03
no abstracts in English
Usuda, Shigekazu; Watanabe, Kazuo; Sakurai, Satoshi; Magara, Masaaki; Hanzawa, Yukiko; Esaka, Fumitaka; Miyamoto, Yutaka; Yasuda, Kenichiro; Saito, Yoko; Gunji, Katsubumi*; et al.
KEK Proceedings 2001-14, p.88 - 92, 2001/06
no abstracts in English
Adachi, Takeo; Usuda, Shigekazu; Watanabe, Kazuo; Sakurai, Satoshi; Magara, Masaaki; Hanzawa, Yukiko; Esaka, Fumitaka; Yasuda, Kenichiro; Saito, Yoko; Takahashi, Masato; et al.
IAEA-SM-367/10/02 (CD-ROM), 8 Pages, 2001/00
no abstracts in English
; *; ; ; Aoto, Kazumi;
JNC TN9400 2000-059, 43 Pages, 2000/05
The purpose of this study is to understand the material properties of manufacturable high-purity iron and high-purity iron-based alloy in present technology and to get an applicable prospect for the structural and functional material of the frontier fast reactor. Then the about 10kg high-purity iron and iron-based alloy were melted using a cold-crucible induction melting furnace under the ultra-high vacuum. Subsequent to that, the compatibility between the melted material and the high-temperature sodium environment which is a special feature of the fast reactor and tensile property at room and elevated temperatures were investigated using the melted materials. Also, the creep test using the high-purity 50%Cr-Fe alloy at 550C in air in order to understand the high temperature creep property. ln addition, the material properties such as thermal expansion coefficient, specific heat and electrical resistance were measured and to evaluate the outlook for the structural material for the fast reactor. The following results were obtained based on the property test and evaluation. (1)lt was possible to melt the about 10kg high-purity ingot and high-purity 50%Cr-Fe alloy ingot using a cold-crucible induction melting furnace under the ultra-high vacuum. (2)The tensile tests of the high-purity 50%Cr-Fe alloy were performed at room and elevated temperatures in order to understand the deformation behavior. From the experimental results, it was clear that the high-purity 50%Cr-Fe alloy possesses high strength and good ductility at elevated temperatures. (3)The physical properties (the thermal expansion coefficient and specific heat etc.) were measured using the high-purity 50%Cr-Fe alloy. lt was clear that the thermal expansion coefficient of high-purity 50%Cr-Fe alloy was smaller than that of SUS304. (4)From the corrosion test in liquid sodium, the ordinary-purity iron showed the weight loss after corrosion test. However the high-purity iron showed ...
Usuda, Shigekazu; Adachi, Takeo; Watanabe, Kazuo; Magara, Masaaki; Hanzawa, Yukiko; Esaka, Fumitaka; Miyamoto, Yutaka; Yasuda, Kenichiro; Gunji, Hideho; Tsuruta, Yasuhiro; et al.
Proceedings of Seminar on Strengthening of Safeguards: Integrating the New and the Old, p.477 - 481, 2000/00
no abstracts in English
Hanzawa, Yukiko; Magara, Masaaki; Esaka, Fumitaka; Watanabe, Kazuo; Usuda, Shigekazu; Miyamoto, Yutaka; Gunji, Katsubumi; Yasuda, Kenichiro; Nishimura, Hideo; Adachi, Takeo
Proceedings of OECD/NEA Workshop on Evaluation of Speciation Technology, p.167 - 172, 1999/00
no abstracts in English
Hanzawa, Yukiko; Magara, Masaaki; Esaka, Fumitaka; Watanabe, Kazuo; Usuda, Shigekazu; Gunji, Katsubumi; Yasuda, Kenichiro; Takahashi, Tsukasa; Nishimura, Hideo; Adachi, Takeo; et al.
Proceedings of the Institute of Nuclear Materials Management 40th Annual Meeting (CD-ROM), 7 Pages, 1999/00
no abstracts in English
Miyamoto, Yutaka; Yasuda, Kenichiro; Magara, Masaaki
no journal, ,
The authors accomplished the development of technique for sequential separation of U, Th, Pb, and the lanthanides using a single anion-exchange column and mixed media consisting of hydrochloric acid, nitric acid, acetic acid, and hydrofluoric acid in the previous work. Composition of eluents for separation of Pu and Th was optimized to accomplish the sequential separation of multi-elements including Pu. The mixture of Pu and Th was successfully separated by a single anion exchange column with acetic acid-HCl-HF mixed-media.
Miyamoto, Yutaka; Yasuda, Kenichiro; Magara, Masaaki
no journal, ,
In order to analyse the environmental records of key elements including radioactive isotopes which originates from nuclear bomb tests and accidental releases from nuclear power plants, the authors accomplished the development of technique for automatic and sequential separation of less than nano grams of ultra-trace U, Th, Pb, the lanthanides, and Pu using a single anion-exchange column and mixed media consisting of highly pure acids. The separation performance of ion-exchange column was evaluated using the spikes and a reference solution, and the automatic separation system was served for the elemental and isotopic analyses of ultra-trace elements in the tree ring samples.